Calibration Options
EOC Calibration
(Not Accredited)

Before and After Results.
Repeatability per B89
X, Y and Z Linear Accuracy per
B89.
Squareness / Perpendicularity
Volumetric Accuracy (15 position
ball-bar) if OEM Specifies.
Hard Measurement Data.
Calibration Sticker
Calibration Certificate
Traceable to N.I.S.T
Adjustments are made to meet
OEM Spec.

Includes Preventative
Maintenance after the before
measurements.
Clean and inspect Fans, Filters,
Airlines, Scales and Way Surfaces.
Check and adjust read heads and
signals.
Inspect and adjust Fine Feeds, Air
/ Hard Bearings, Counterbalance,
Machine Level and Failsafe.
Inspect Power Supplies for AC
Ripple and proper Voltage.
Recommendations will be made
for repairs if needed.
ISO/IEC 17025 Calibration

Per B89.4.1b-2001 and OEM
specifications.
Measurement Uncertainty for all
test’s.
Before and After Results.
Repeatability per B89.
X, Y and Z Linear Accuracy per
B89.
Squareness / Perpendicularity.
Volumetric Accuracy per B89 if
OEM Specifies.
Linear Temperature Compensation
to 68F.
Approved Test Sheets.
Approved Preliminary and Final
Certificates.
Approved Calibration Sticker.
Hard Measurement Data.
Meets A2LA Traceabilty Policy.
The Quality Manger reviews Final
Certificate.
Meets QS9000, ISO and ISO/TS
requirements.
Adjustments are made to meet OEM
Spec.

Includes Preventative
Maintenance after the before
measurements.
Clean and inspect Fans, Filters,
Airlines, Scales and Way Surfaces.
Check and adjust read heads and
signals.
Inspect and adjust Fine Feeds, Air /
Hard Bearings, Counterbalance,
Machine Level and Failsafe.
Inspect Power Supplies for AC
Ripple and proper Voltage.
Recommendations will be made for
repairs if needed.
Factory Calibration
(Not Accredited)

No Before Measurements.
Repeatability per B89
X, Y and Z Linear Accuracy per
B89.
Squareness / Perpendicularity
Volumetric Accuracy (15 position
ball-bar) if OEM Specifies.
Hard Measurement Data.
Calibration Sticker
Calibration Certificate
Traceable to N.I.S.T
Adjustments are made to meet
OEM Spec.

Includes Preventative
Maintenance before
measurements are taken.
Clean and inspect Fans, Filters,
Airlines, Scales and Way Surfaces.
Check and adjust read heads and
signals.
Inspect and adjust Fine Feeds, Air
/ Hard Bearings, Counterbalance,
Machine Level and Failsafe.
Inspect Power Supplies for AC
Ripple and proper Voltage.
Recommendations will be made for
repairs if needed.
Servo Option

Full Servo Preventative
Maintenance Includes:
Inspect Motors.
Inspect Belts and Alignment of
Drives.
Check Bearing Wear
Check Kv parameters
Check Positioning
Check Balance
Check Slip
Check overshoot
Belt Tension
Adjustments will be made if
needed to the inspected items.
Recommendations will be made for
repairs if needed.
Z Roll Option

Z Axis Roll Performance Test.
Recommended for customers
who utilize long offset probe
extensions.
Volumetric Accuracy per B89
Step Gage Linear Accuracy per B89
(CMM Service)
(CMM Part Inspection)
(CMM Retrofits/Rebuilds)
(CMM Calibration)